Ultra-low-dose computed tomography and its utility in wrist trauma in the emergency department


Tekin E., Tuncer K., Ozlu İ., Sade R., Pirimoglu R. B., Polat G.

ACTA RADIOLOGICA, cilt.63, sa.2, ss.192-199, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 63 Sayı: 2
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1177/0284185121989958
  • Dergi Adı: ACTA RADIOLOGICA
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, CINAHL, Compendex, EMBASE, MEDLINE
  • Sayfa Sayıları: ss.192-199
  • Anahtar Kelimeler: Ultra-low-dose computed tomography, multidetector computed tomography, wrist fracture, emergency departments, trauma, CT, RADIOGRAPHY, FRACTURES, DIAGNOSIS, PROTOCOL, QUALITY
  • Atatürk Üniversitesi Adresli: Evet

Özet

Background The use and frequency of computed tomography (CT) are increasing day by day in emergency departments (ED). This increases the amount of radiation exposed. Purpose To evaluate the image quality obtained by ultra-low-dose CT (ULDCT) in patients with suspected wrist fractures in the ED and to investigate whether it is an alternative to standard-dose CT (SDCT). Material and Methods This is a study prospectively examining 336 patients who consulted the ED for wrist trauma. After exclusion criteria were applied, the patients were divided into the study and control groups. Then, SDCT (120 kVp and 100 mAs) and ULDCT (80 kVp and 5 mAs) wrist protocols were applied simultaneously. The images obtained were evaluated for image quality and fracture independently by a radiologist and an emergency medical specialist using a 5-point scale. Results The effective radiation dose calculated for the control group scans was 41.1 +/- 2.1 mu Sv, whereas the effective radiation dose calculated for the study group scans was 0.5 +/- 0.0 mu Sv. The effective radiation dose of the study group was significantly lower than that of the control group (P < 0.01). The CT images in the study group showed no significant differences in the mean image quality score between observer 1 and observer 2 (3.4 and 4.3, respectively; P = 0.58). Both observers could detect all fractures using the ULDCT images. Conclusion ULDCT provides high-quality images in wrist traumas while reducing the radiation dose by approximately 98% compared to SDCT without any changes in diagnostic accuracy.