Experimental investigation of courgette drying performance in an air-to-air cascade heat pump system with variable internal air circulation
Heat and Mass Transfer/Waerme- und Stoffuebertragung, cilt.62, sa.12, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 62 Sayı: 12
- Basım Tarihi: 2026
- Doi Numarası: 10.1007/s00231-026-03823-0
- Dergi Adı: Heat and Mass Transfer/Waerme- und Stoffuebertragung
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Aerospace Database, Chimica, Compendex, INSPEC, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO), Materials Science & Engineering Collection (ProQuest), Technology Collection (ProQuest)
- Atatürk Üniversitesi Adresli: Evet
Özet
Despite growing interest in heat pump drying technologies, limited experimental research has investigated the influence of variable internal air circulation on the drying performance, moisture removal characteristics, and energy efficiency of air-to-air cascade heat pump systems. This study experimentally investigates the drying performance of an air-to-air cascade heat pump drying system. The experimental setup incorporated a low-power internal air circulation device to improve airflow distribution and facilitate moisture removal during agricultural product drying. A laboratory-scale drying chamber integrated with a cascade heat pump was fabricated to provide the thermal energy required for the drying of courgette. To enhance airflow distribution and moisture transport within the chamber, a 12 V fan was installed. The fan was operated at different voltage levels including 4, 6, and 8 V. Drying experiments were conducted using 700 g of fresh sliced courgette under controlled indoor conditions over 5 h. The effects of internal air circulation on drying characteristics, moisture removal, drying efficiency, specific moisture extraction rate (SMER), power consumption, and coefficient of performance (COP) were evaluated and results were compared with a fanless reference condition. The results showed that the cascade heat pump provided stable drying air temperatures, reaching approximately 48 °C after 120 min of experiment. Increasing the air circulation intensity significantly improved moisture removal from the product. After 5 h of drying, the final sample weights decreased from approximately 518 g under fanless conditions to 463 g, 442 g, and 419 g at 4 V, 6 V, and 8 V fan voltages, respectively. The experimental results indicated that the COP of the cascade heat pump drying system generally remained below 2, and SMER varied between approximately 0.20 and 0.32 kg/kWh under the investigated operating conditions.