Combination of fan ventilation system and spraying of oil-water mixture on the levels of dust and gases in caged layer facilities in Eastern Turkey
JOURNAL OF APPLIED ANIMAL RESEARCH, cilt.27, sa.2, ss.109-111, 2005 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 27 Sayı: 2
- Basım Tarihi: 2005
- Doi Numarası: 10.1080/09712119.2005.9706551
- Dergi Adı: JOURNAL OF APPLIED ANIMAL RESEARCH
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.109-111
- Anahtar Kelimeler: caged layer houses, dust, gases, oil-water application, ventilation
- Atatürk Üniversitesi Adresli: Evet
Özet
To reduce harmful gases such as CO2, NH3 and H2S and dust in caged layer houses in Eastern Turkey, spraying of sunflower oil-water mixture and fan ventilation were investigated. It is demonstrated that these treatments together may improve air of the caged layer houses.