Effective atomic numbers, water and tissue equivalence properties of human tissues, tissue equivalents and dosimetric materials for total electron interaction in the energy region 10 keV-1 GeV


Kurudirek M.

APPLIED RADIATION AND ISOTOPES, cilt.94, ss.1-7, 2014 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 94
  • Basım Tarihi: 2014
  • Doi Numarası: 10.1016/j.apradiso.2014.07.002
  • Dergi Adı: APPLIED RADIATION AND ISOTOPES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1-7
  • Anahtar Kelimeler: Effective atomic number, Total electron interaction, Water equivalence, Tissue equivalence, MASS ATTENUATION COEFFICIENTS, PHOTON INTERACTION, ABSORPTION, DENSITIES, RANGE
  • Atatürk Üniversitesi Adresli: Evet

Özet

Effective atomic numbers (Z(eff)) of 107 different materials of dosimetric interest have been calculated for total electron interactions in the wide energy region 10 key-1 GeV. The stopping cross sections of elements and dosimetric materials were used to calculate Z(eff) of the materials. Differences (%) in Z(eff) relative to water have been calculated in the entire energy region to evaluate the water equivalency of the used materials. Moreover, the tissue equivalent materials have been compared with the tissues and dosimetric materials in terms of Z(eff) to reveal their ability to use as tissue substitutes. Possible conclusions were drawn based on the variation of Z(eff) through the entire energy region and water and tissue equivalency comparisons in terms of Z(eff). (C) 2014 Elsevier Ltd. All rights reserved.