Broadband permittivity determination of soil using a low-cost modular measurement system by amplitude-only transmission measurements


Hasar U. C., Ali H., KAYA Y., Nayyeri V.

Measurement: Sensors, cilt.48, 2026 (Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 48
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1016/j.measen.2026.102030
  • Dergi Adı: Measurement: Sensors
  • Derginin Tarandığı İndeksler: Scopus
  • Anahtar Kelimeler: Amplitude, Broadband, Complex permittivity, Correlation curve, Frequency-domain spectroscopy, Low-cost, Modular system, Soil moisture
  • Atatürk Üniversitesi Adresli: Evet

Özet

A modular measurement system is developed for permittivity determination of relatively lossy soil samples positioned on a supporting plug within a hollow coaxial transmission line (EIA 1-5/8”). The system is capable of performing broadband amplitude-only transmission measurements while requiring simple calibration procedure based on amplitude normalization. The underlying expressions needed to determine permittivity are derived using amplitude-only transmission measurements of two samples with different lengths. It is demonstrated by a numerical analysis that the proposed method can evaluate one permittivity of samples introducing at least −10 dB attenuation by simultaneous solution of two objective functions derived for each of sample lengths. Other numerical analyses are also performed to evaluate how smoothly the solution can be evaluated for a global minimum, analyze how the accuracy changes when the attenuation approaches −10 dB, interrogate the sample packing influence, and examine whether our method is effective for permittivity determination of dispersive samples (to reflect moisturized soil samples). The measurement system mainly comprises a microwave source (MAX2870 from Analog Devices with a frequency range up to 6 GHz), a detector (AD8317 from Analog Devices), and a Raspberry Pi Pico to operate them (without any need for complex measurements and directional coupler). Compared with similar studies based on reflection-measurements by low-cost nano-VNA units with an average cost of 500€, our system has a much lower cost around 30$ while performing relatively accurate measurements. Performance of the measurement system is validated by permittivity measurements over 1:3 GHz of soil samples having more than 90% sand content and different moisture levels (and distilled water). Its performance was also examined by the Mironov–Fomin model (measured and predicted difference is less than 3.6%) and tested by the comparing the constructed permittivity-moisture correlation curve with those established by other studies, some of which use expensive and commercial VNA instruments.