The effect of curing conditions on some mechanical properties of perlite concrete


SAĞSÖZ A. E., GÜL R., AYDIN A. C.

1st International Conference on Civil Engineering - Towards a Better Environment, CE 2009 and the 4th International Conference on the Concrete Future, CF 2009, Coimbra, Portekiz, 17 - 19 Haziran 2009, (Tam Metin Bildiri)

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Basıldığı Şehir: Coimbra
  • Basıldığı Ülke: Portekiz
  • Anahtar Kelimeler: Atmospheric steam curing, Compressive strength, Perlite concrete, Ultrasonic pulse velocity
  • Atatürk Üniversitesi Adresli: Evet

Özet

The effect of air, water and atmospheric steam curing conditions on raw perlite concrete was investigated. The characteristic strengths of perlite concretes were C20 and C30. Three different periods of 7, 14, and 28 days were applied for the samples exposed to water and air curing. For the samples exposed to steam curing, three different temperatures of 65°C, 75°C, and 85°C and three different periods of 6, 12, and 24 hours were applied. For the samples prepared by these methods, compressive strength and ultrasonic pulse velocity experiments were performed in this study. As a result, compressive strength and ultrasound transient velocity values were increased as the air and water curing period increased for raw perlite concrete. Steam cured samples, compressive strength and ultrasound transient velocity values increased with rising curing period and temperature. Air and atmospheric steam curing samples were compared with water cured samples (control samples). Moreover, an exponential relationship was determined between the compressive strength and ultrasonic pulse velocity.