Hydroxyapatite/graphene oxide–palladium composite coatings on Ti–12Cr alloy prepared by hydrothermal method: surface characteristics, antibacterial activity, and corrosion behavior
Surfaces and Interfaces, cilt.102, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 102
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.surfin.2026.111209
- Dergi Adı: Surfaces and Interfaces
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, INSPEC
- Anahtar Kelimeler: Ti-12Cr alloy, Hydroxyapatite coating, Graphene oxide, Palladium, Hydrothermal synthesis, Corrosion behavior, Wettability, Staphylococcus aureus, Antibacterial behavior
- Atatürk Üniversitesi Adresli: Evet
Özet
In this study, hydroxyapatite (HA)-based composite coatings containing graphene oxide (GO) and palladium (Pd) were deposited on Ti–12Cr alloy by a hydrothermal route and comparatively evaluated for structural and surface characteristics, wettability, electrochemical response, MC3T3-E1 preosteoblast response, and antibacterial behavior. XRD, Raman, FT-IR, SEM/EDS, and XPS analyses supported the formation of HA-based coatings containing GO-related carbon features and Pd. Representative high-resolution XPS of the HA/GO–2 wt.% Pd coating resolved the characteristic Ca 2p and P 2p environments of the calcium-phosphate phase, oxygenated carbon components associated with GO, and mixed Pd⁰/Pd²⁺ surface states. The C 1s and O 1s components demonstrate the coexistence of oxygenated GO-related functionalities and calcium-phosphate oxygen environments within the XPS surface-sampling region, but they do not uniquely establish specific Ca–O–C or P–O–C interfacial linkages. Top-view SEM showed composition-dependent morphological changes, with layered regions and elongated rod-/needle-like surface features in the GO-containing coatings; these observations were not interpreted as crystallographic grain refinement. ICP-MS of scraped coating powders quantified total Pd contents of 0.814 and 1.587 wt% in the HA–1 wt.% Pd and HA–2 wt.% Pd coatings and 0.902 and 1.776 wt% in the corresponding GO-containing coatings, respectively. These measurements confirm composition-dependent total Pd loading but do not establish Pd release behavior. In the single-dataset electrochemical comparison in Hank’s balanced salt solution at 37 ± 0.5°C, HA/GO showed the numerically highest polarization resistance and lowest corrosion rate among the six coated groups, while increasing Pd content was accompanied by progressively lower polarization resistance within the GO-containing series. Because no uncoated Ti–12Cr control was included and only one complete polarization dataset was available for each coating composition, these electrochemical trends are descriptive numerical comparisons only; they were not subjected to inferential statistical testing and should not be interpreted as statistically proven effects of GO or Pd or as established improvement over the bare alloy. In the MC3T3-E1 assay, all HA-based coatings exhibited higher surface-associated cell density than the uncoated Ti–12Cr material control, with the highest values observed for HA/GO and HA/GO–1 wt.% Pd after 72 h. In addition to qualitative Pseudomonas aeruginosa Xen5 screening, quantitative Staphylococcus aureus ATCC 25923 testing after 24 h showed relative bacterial viabilities of 97 ± 6% for HA, 76 ± 6% for HA–1 wt.% Pd, 55 ± 5% for HA–2 wt.% Pd, 88 ± 6% for HA/GO, 40 ± 5% for HA/GO–1 wt.% Pd, and 26 ± 3% for HA/GO–2 wt.% Pd, compared with 100 ± 8% for uncoated Ti–12Cr. Live/Dead staining qualitatively supported the composition-dependent decrease in bacterial survival. Pd release was not quantified and MRSA was not tested; therefore, the relative contributions of contact- and release-mediated effects, the safe Pd exposure window, long-term biosafety, and broad-spectrum antibacterial efficacy remain unresolved. Overall, the results identify composition-dependent trade-offs among surface chemistry, electrochemical behavior, preosteoblast response, and antibacterial performance, while further release, multi-strain, cross-sectional, mechanical, and longer-term osteogenic studies are required before clinical applicability can be established.