BIOMEDICAL CHROMATOGRAPHY, cilt.30, sa.6, ss.946-952, 2016 (SCI-Expanded)
Method validations in addition to decline patterns of fluquinconazole and flusilazole in lettuce grown under greenhouse conditions at two different locations were investigated. Following the application of fluquinconazole and flusilazole at a dose rate of 20mL/20L water, lettuce samples were collected randomly for up to 7days post-application, and simultaneously extracted with acetone, purified through solid-phase extraction, analyzed via gas chromatography with a nitrogen phosphorus detector, and confirmed through gas chromatography-mass spectrometry. The linearity was excellent, with determination coefficients (R-2) between 0.9999 and 1.0. The method was validated in triplicate at two different spiking levels (0.2 and 1.0mg/kg) with satisfactory recoveries between 75.7 and 97.9% and relative standard deviations of <9. The limit of quantification was 0.01mg/kg. Both analytes declined very quickly, as can be seen from the short half-life time of <4days. Statistical analysis revealed significant differences between residues at different days of sampling, except at 7days post-application (triple application). At that point, the decline patterns of fluquinconazole and flusilazole were independent of application rate, location, temperature and humidity. Copyright (c) 2015 John Wiley & Sons, Ltd.