Evaluation of 4 Point-of-Care Units for the Determination of Blood L-Lactate Concentration in Cattle
JOURNAL OF VETERINARY INTERNAL MEDICINE, cilt.27, sa.6, ss.1596-1603, 2013 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 27 Sayı: 6
- Basım Tarihi: 2013
- Doi Numarası: 10.1111/jvim.12204
- Dergi Adı: JOURNAL OF VETERINARY INTERNAL MEDICINE
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.1596-1603
- Anahtar Kelimeler: Accuracy, Bovine, Portable lactate meter, Precision, Sensitivity, Specificity, PLASMA LACTATE, PROGNOSTIC VALUE, DAIRY-COWS, REGRESSION PROCEDURES, LEAST-SQUARES, WHOLE-BLOOD, DOGS, VOLVULUS, CALVES, ANALYZER
- Atatürk Üniversitesi Adresli: Evet
Özet
BackgroundDespite being used commonly in bovine medicine, information on reliability of point-of-care (POC) lactate meters is limited.