Development and validation of a sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry method for quantitative analysis of bambermycin in livestock and aquatic products: Implications for food safety control and regulatory enforcement


Park D., Cho H., Kang S., Lee H., Shin J., HASSIBELNABY A. M. A., ...Daha Fazla

Journal of Separation Science, cilt.46, sa.20, 2023 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 46 Sayı: 20
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1002/jssc.202300377
  • Dergi Adı: Journal of Separation Science
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, PASCAL, Aerospace Database, BIOSIS, CAB Abstracts, Chemical Abstracts Core, Chimica, Communication Abstracts, Compendex, Food Science & Technology Abstracts, INSPEC, MEDLINE, Metadex, Veterinary Science Database, Civil Engineering Abstracts
  • Anahtar Kelimeler: antibiotic residues, aquatic products, livestock products, method development, tandem mass spectrometry
  • Atatürk Üniversitesi Adresli: Evet

Özet

A sensitive and accurate analytical method was developed and validated to detect bambermycin, a commonly used antibiotic in animal feed and livestock. The presence of bambermycin residues in food products can pose health risks to consumers, emphasizing the need for a sensitive and accurate analytical method. A reversed-phase analytical column was utilized with a mobile phase comprising 0.005 mol/L ammonium acetate in 5% acetonitrile (A) and 0.005 mol/L ammonium acetate in 95% acetonitrile (B) to achieve effective chromatographic separation. Quantitative determination of bambermycin in various samples, including beef, pork, chicken, milk, eggs, flatfish, eel, and shrimp, was performed using ultra-high-performance liquid chromatography-tandem mass spectrometry. Sample extraction involved a mixture of methanol and a 25% ammonium hydroxide solution, followed by low-temperature purification and phospholipid removal utilizing a Phree cartridge. The method exhibited a satisfactory recovery rate ranging from 69% to 100%. Validation results demonstrated the reliability, robustness, and accuracy of the method, exhibiting good linearity, precision, and recovery. This validated method can be applied for routine analysis of bambermycin residues, assisting in the development of effective monitoring and control measures to ensure the safety of livestock and aquatic products.